Tree phase DC voltage measuting transducers.E3855 can be used without external primary transformers.
№ | Type | Measured voltage, V | Iout., mA |
Load resistance, Ohm | Iconsump. for each measured circuit, mA | Рconsump. for supply circuit, VA | Accuracy class |
1 | Е3855А | 0..125 (75..125) | 0..5 | 0 – 3000 | not more than 1 | not more than 5 | 0,5 |
0..125√3 (75√3..125√3) | |||||||
0..250√3 (150√3..250√3) | |||||||
0..400√3 (240√3..400√3) | |||||||
2 | Е3855В | 0..125 (75..125) | 4..20 | 0 – 500 | |||
0..125√3 (75√3..125√3) | |||||||
0..250√3 (150√3..250√3) | |||||||
0..400√3 (240√3..400√3) | |||||||
3 | Е3855С | 0..125 (75..125) | 0..20 | 0–500 | |||
0..125√3 (75√3..125√3) | |||||||
0..250√3 (150√3..250√3) | |||||||
0..400√3 (240√3..400√3) |
Dimentions 120х80х77 mm
Weight not more than 0,6 kg.
Power supply – AC 187-242V 50 Hz frequency.
Time of setting output signal in case of input signal hopping to any value in measured range – not more than 0,5 s.
Time of setteng working condition – not more than 10 min.
Worktime between failures – not less than 50 000 h.
Average lifetime – not less than 10 years.
Note: additional measuring transformers-free usage is possible.
Three output cascades are galvanically unlinked between each other and input cascades..
Additional measuring range (pointed in brackets) can be selected with external cross-piece.
Е3855 indexes:
Е3855А - output current (0..5) mA
Е3855В - output current (4..20) mA
Е3855С - output current (0..20) mA
Electrochemical power source Activator (Activator) is intended for battery maintenance, training and state checking.