rus | eng
tel.: +7 (3812) 37-22-37, 31-00-33

Копия Measuring transducer AEDC857

Measuring transducer AEDC857

Description AEDC857

Meant for measuring DC voltage and transducing results into unified DC signals and into digital code for transmition to upper level of automated systems.

Can be used in automated manufacturing systems for control of processes.

Can be used for control of energetic and industrial factories including dangerous manufacturing.

Inputs and outputs are galvanically unlinked.

 

Decoding:

AEDC857A-RS-100

AEDC857 Output, mA - RS485 - Measured range, V
A 0 - 5 Empty  No RS485 60
B 4 - 20 RS RS485 presents 100
C 0 - 20     150
        250
        500
        1000

 

Brief specifications:

Model Measured voltage, V Output current, mA Load resistance,Ω Basic error limits
analogue output γ, % digital output, Δ
AEDC857A-60
0..60 0 - 5 0 - 3000 ± 0,5
AEDC857A-RS-60
±(0,003 Аin + 0,06) mV
AEDC857A-100
0..100 0 - 5 0 - 3000 ± 0,5
AEDC857A-RS-100
±(0,003 Аin + 0,1) mV
AEDC857A-150
0..150 0 - 5 0 - 3000 ± 0,5
AEDC857A-RS-150
±(0,003 Аin + 0,15) mV
AEDC857A-250
0..250 0 - 5 0 - 3000 ± 0,5
AEDC857A-RS-250
±(0,003 Аin + 0,25) mV
AEDC857A-500
0..500 0 - 5 0 - 3000 ± 0,5
AEDC857A-RS-500
±(0,003 Аin + 0,5) mV
AEDC857A-1000
0..1000
0 - 5 0 - 3000 ± 0,5
AEDC857A-RS-1000
±(0,003 Аin + 1) mV
AEDC857B-60 0..60 4 - 20 0 - 500 ± 0,5
AEDC857B-RS-60
±(0,003 Аin + 0,06) mV
AEDC857B-100 0..100 4 - 20 0 - 500 ± 0,5
AEDC857B-RS-100
±(0,003 Аin + 0,1) mV
AEDC857B-150 0..150 4 - 20 0 - 500 ± 0,5
AEDC857B-RS-150
±(0,003 Аin + 0,15) mV
AEDC857B-250
0..250 4 - 20 0 - 500 ± 0,5
AEDC857B-RS-250
±(0,003 Аin + 0,25) mV
AEDC857B-500
0..500 4 - 20 0 - 500 ± 0,5
AEDC857B-RS-500
±(0,003 Аin + 0,5) mV
AEDC857B-1000
0..1000
4 - 20 0 - 500 ± 0,5
AEDC857B-RS-1000
±(0,003 Аin + 1) mV
AEDC857C-60 0..60 0 - 20 0 - 500 ± 0,5
AEDC857C-RS-60
±(0,003 Аin + 0,06) mV
AEDC857C-100 0..100 0 - 20 0 - 500 ± 0,5
AEDC857C-RS-100
±(0,003 Аin + 0,1) mV
AEDC857C-150 0..150 0 - 20 0 - 500 ± 0,5
AEDC857C-RS-150
±(0,003 Аin + 0,15) mV
AEDC857C-250 0..250 0 - 20 0 - 500 ± 0,5
AEDC857C-RS-250
±(0,003 Аin + 0,25) mV
AEDC857C-500 0..500 0 - 20 0 - 500 ± 0,5
AEDC857C-RS-500
±(0,003 Аin + 0,5) mV
AEDC857C-1000 0..1000 0 - 20 0 - 500 ± 0,5
AEDC857C-RS-1000
±(0,003 Аin + 1) mV

Catalog:

Electrochemical power source Activator (Activator) is intended for battery maintenance, training and state checking.

Electrochemical power sources (batteries) analyzer
Digital multifunctional measuring transducers (standard and budget versions)
Measuring transducers with unified current output. (13)
AEDC are meant for measuring DC current and DC voltage. Analogue current input and RS-485 interface. (3)
Indication devices AED and AEGD are meant for connecting to measuring regenerator AET to indicate measuring results. (2)